Some of our most common requested tips and troubleshooting requests are listed below to help you diagnose or fix any issues that are frequently seen in the specific piece of equipment below.
Don’t see what your looking for? Feel free to contact one of our techs and submit your question using the form on the right hand side of this page.
Initial Trouble shooting tips
1) Check the main power switch in the cab the one with the lightning bolt
2) Check fuse
Initial Trouble shooting tips
1) is the FNR handle in neutral, check the operation of the neutral start switch while starting the engine. It should only crank the engine over when the lever is in neutral
2) check if the function is activated/turned on via the display
3) check the sensor point counts/position. Sensors need to be between 150 and 950. Needs to show calibrated numbers for the auto fold to work. Calibrate the autofold
Initial Trouble shooting tips
1)check switches at the remote fill station
2)remote fill station light switch must be in the “off” position
3)remote fill station pump switch must be in the “auto” position
Initial Trouble shooting tips
1) Check for any leaks in the spray system
2) Check all spray system filters to ensure they are clean
3) Double check that all valves are in the correct positions, refer to chart on side of sprayer